Natural Gas Industrial Gas Meter Thread End Flow Meters

Thermal-Mass-Flow-Meters-India-2-min.jpg
  • No moving parts
  • Exclusive inline sensor
  • Advanced signal processing electronics
  • Field adjustable; easy onsite calibration adjustments
  • Maintenance-free
  • Easy installation
  • Choice of wetted materials
  • Long-term reliability
  • Stores up to four calibration curves
  • Extended temperature compensation
  • Optional remote electronics configuration
  • Hazardous environment options
Flanged-End-Flow-Meters-min.jpg

Natural Gas Flow Meter Flanged End-Thermal Mass Flow Meters

  • No moving parts. No Mainatainance.Long Product Life. 2 Years Warranty.
  • Exclusive inline sensor. Stainless Steel 304 MOC For All Parts.
  • Advanced signal processing electronics
  • Field adjustable; easy onsite calibration adjustments
  • Maintenance-free
  • Easy installation
  • Choice of wetted materials
  • Long-term reliability
  • Stores up to four calibration curves. For Turndown ratios Upto 1:200 True Turndown.
  • Extended temperature compensation
  • Optional remote electronics configuration
  • Hazardous environment options
  • Cost Effective
  • Inline Flow Straightners & Laminar Flow Elements Inbuilt.

Natural Gas Bulk Metering & Bulk Installiations/Metering. Insertion Thermal Mass Flow Meter For Natural Gas Flow Measurement.

Insertion-Type-Flow-Meters-min.jpg
  • No moving parts
  • Insert Into Pipeline.
  • Advanced signal processing electronics
  • Field adjustable; easy onsite calibration adjustments
  • Maintenance-free
  • Easy installation
  • Choice of wetted materials
  • Long-term reliability
  • Stores up to four calibration curves
  • Extended temperature compensation
  • Optional remote electronics configuration
  • Hazardous environment options
  • Easy Installation
  • Low Cost & Accurate.
  • No Pipe Cuts/ Immidiate Installation.
  • Easy Availablity.
  • Fits From 1/2 Inch to 6 Inch Line Sizes
  • Best Suited For Multiple Installations.

Digital Natural Gas Flow Meters Manufacturers & Exporters India.

Our Page Will Display The Information About

  • natural gas flow meter types

  • natural gas flow meter price

  • natural gas flow meter calibration

  • natural gas flow meter selection

  • natural gas flow meter totalizer

  • low cost natural gas flow meter

  • natural gas flow meter suppliers

  • natural gas thermal mass flow meter

Precision Flow 's Thermal flow meters are an excellent—often the Only Best—choice for Reliable Gas Flow Measurement For Natural Gas Flow Measurement. Typically We Offer Thermal Mass Flow Meters In Four Catagories/Options.

Inline Thermal Mass Flow Meter With Head-Top Display,

Insertion Type Flow Meters With Top Display,

Remote Display Inline Flow Meters
Remote Display Insertion Type Flow Meters.
Flow measurement with little or no maintenance. All Standard rFlow Meters are for hazardous locations (intrinsically safe/explosion-proof) Precision Flow Control Instruments, a leader in manufacturing Mainly For Gas Flow Measurement With Inhouse Caliberation Facilities & Inline Flow Accuracy Measuring Methods. All of our Laboratory Thermal flow instruments are backed by an Highly Accurate Caliberation Lab & Long term Research and Development Experience.


We are Suppliers to Around 300 + Limited Organisations In India And We Export Through Channels to Many Different Regions.

Inline Thermal Mass Flow Meters:- One OEM Solution Supplier For All Your Critical Flow Measurement & Control Requirements.Unique Solution To Exteme Flow Measurement & Customised Requirements. Inline Thermal Mass Flow Meters With Inline Display Offered By Precision Flow Control Instruments are Extremely High Accurate. The Accuracy Ranges From 0.5 % Full Scale Upto 1.00% Full Scale Back Fully Reliable Across Entire Period Of Two Years.

Insertion Type Thermal Mass Flow Meters:- One More Solution We Offer Is The Thermal Mass Flow Meter With Insert Type Option., Typically Used Where The Lines Cannot Be Cut Or Bulk Installiations Where Enough Of Piping Is Available . It Reduces The Piping Costs and Can Be Mounted Easily In Any Pipe Right From 1 Inch to 6 Inch Diameters In a Single Unit Simultaneously Reducing The Cost and Offering A Overall Cost Effective Flow Measurement Solution.

The Third Type Of Flow Meter Solution We Offer is The Non Contact Thermal Mass Flow Meters Which are A Step Furthur In Our Research and Development Of Years Is Concerned. The Non Contact Type Thermal Mass Flow Meters are Extremely Reliable Flow Meters Which Can Be Operated At Extremely High Pressures Like Upto 300 Bar Guage Pressures and Offer The Same Accuracy and Repatablity As The Inline Thermal Mass Flow Meters Offer. As There is No Contact With The Transmitters There is no Breakage Or Damage To The Transmitters, And There is No Effect As Such. Non Contact Thermal Mass Flow Meters Are Customised Manufactured , Cost Effective, Long Term Reliable, Non Breakable, And No path Blockage, No Moving Parts , Less Maintanance & Highly Effective to Accurate Flow Metering Of Natural Gas is Concern.

Thermal Mass Flow Meters are Caliberated With Extreme Precision . The Masters We Consider Need to Be Atleast Times Accurate Than What we Offer, So As to Always Think Of The Best Performance Considering The Accuracy. The Thermal Mass Flow Meters are Caliberated Inline on The Flow Bench. A Known Master Flow is Passed Through The Master Flow Meter and Then The Signal Output Is Recorded Which Is Then Programmed into The Totalizer Unit Which Then Displays The Readings & Flow Rates. The Thermal Mass Flow Meter For Natural Gas Is Mostly Caliberated On Weighing Scales Using The Weight Loss Principle and The Time Constant., A Weighing Scale accuracy Of Better Than 0.1% or Class I Scales.Which are Specially Suitable For Precise Laboratory Applications. By The Use Of Precise Basic Primary Caliberation Master We Can Offer Better Than 0.5 % Accuracy and Sometimes better Than That. Each Reading Is Recorded and Preserved For The Duration Till The Caliberation Certificate is Valid. We Often Caliberated The Flow Meters Every Single Year to Make it Validated. This Can Be Done at The Customers End or At Our Caliberation Labs. We Offer a Small Fee For Caliberations For The Same . This Caliberation Later Is Valid For Furthur Year . The Caliberation Certificate For Every Flow Meter is Given Along with The Flow Meter.

 

Precision Flow Control Instruments Pune.

Selection Of Natural Gas Flow Meters and Points to Be Considered

The Precision Flow Control Instruments Make Thermal Mass Flow Meter / Volume flow meter For Natural Gas is Selected As Per The Requirement Of The Customer. We Generally Consider The Following Points In Order to Select The Best Of The Flow Meter .

  • Line Size: – If The Line Size is Less Than 6 Inches We Can Offer Inline Type Flow Meters.Inline Type Flow Meters Have a Advantage That They Have Inline Laminar Flow Elements Installed  By Default For Almost Every Flow Meter To Enhance The Flow Profile and Eliminate The Turbulance,in The Pipelines.
  • Insertion Type Flow Meters Can Be Offered From 1/2 Inch to 12 Inch Line Sizes With Caliberated At Our Ends For Upto Full Range( 0 to 100 m/s Velocity)
  • Pressure: We Consider The Pressure When Selecting The Flow Meters. For Pressures Upto 10 Bar We Offer Inline/ Insertion Flow Meters. For Pressures More Than That We Offer Non Contact Flow Meters. There Mass Flow Meters are Insensitive to Pressure Changes
  • Temperature: Thermal Mass Flow Meters Work Accurate and Excellent Upto 70 Degree Celcius Of Media Temperatures,. Min  Temperature Range Of 0 Degree and Max of 70 Degree Celcius Offered By us as a Standard.
  • Display Options Needed : We Generally Offer Flow Rate : 4 Digits and Totalizer With 8 Digits Non Resettable Display With No Keypad For Safety.
  • A Communication Option Like The RS485 ., RS422, RS232, USB, & Other Options Like Hart, Bluetooth,Infrared, Zigbee.etc Can Be Offered 
  • Enclosure Options: Mostly When Offering The Natural Gas Flow Meters For Indian Market We Supply Remote Display Enclosure. This Makes The Instruments Twice Safe as Only a Small Voltage Part is Approached to The Flow Meter and Rest All The Electronics Is Located at a Remote Place.The Export Flow Meters Are Offered With Inline Display Options.,
  • Power Supply Options as Standard 230 V AC 50 Hz is Needed For Most of Our Instruments. A Alternative 12 V DC Powered Units are Also Possible
  • End Connections: We Offer Flanged, Threaded, Screwed, & Insertion Type Probe Type Instument Flow Meters
  •  Min and Max Flow Rate: The Turndown Ratio is The Most Intresting Part When Considering To Choose Thermal Mass Flow Meters Than Other Flow Measurement Principles. The Thermal Mass Flow Meters Offer A Minimum Of 1:50 Turndown Ratio and Can Be Furthur Enhanced to 1: 100 With an Accurate Programming
 
 
These Basics Need to Be Understand And Discussed With The End User in Order ot Offer The Perfect Flow Metering Solution.
 
 
 

The Application Environments Where Our Natural Flow Meters are Used.

Industrial Burner Natural Gas Flow Meters.

natural-gas-burners-500x500.jpg
IMG_0088.jpg

Kitchen Natural Gas Flow Meters.

Cars/ Motors Natural Gas Flow Measurement & Extact Tank Level Solutions

Car-Gas.jpg

The Best Features Ever

  • No moving parts
  • Exclusive inline sensor
  • Advanced signal processing electronics
  • Field adjustable; easy onsite calibration adjustments
  • Maintenance-free
  • Easy installation
  • Choice of wetted materials
  • Long-term reliability
  • Stores up to four calibration curves
  • Extended temperature compensation
  • Optional remote electronics configuration
  • Hazardous Environment Enclosures For Every Instrument

How Do They Work?

Like all thermal flow meters, the Thori Thermal analyzes the thermal properties of fluid as it passes through the device to determine the accurate fluid flow rate. Our inline low flow meters use either a straight-through or looped flow tube with two Resistance Temperature Detectors (RTDs)—one heated, the other unheated—attached to the outside of the tube. The temperature differential between the two RTDs provides the primary flow signal. At high flow rates the differential is lower as flow removes heat more readily. At low flow rates the differential is higher because less heat is removed. Because the liquid flows continuously and its composition is homogenous, an accurate flow measurement can be made without the need to gauge the pressure of the fluid.

 

Thermal-Mass-Flow-Sensor-Principle-Of-Working.png
uPDATED-hEADER-min1-1
Micro-Flow.jpg

The unobstructed fluid path ensures that nothing touches the fluid except the flow tube wall, and there are no mechanical parts to wear, stick, or break. The presence of solids in the fluid will not damage the sensor. The Thori Thermal flow meter comes standard with A local display, LCD display that shows the mass/volume flow rate, the temperature (°C or °F), and the total accumulated flow. Flow data can be generated in analog and digital form, and then routed to a digital display or an off-site computer. it also includes a self-diagnostic feature that automatically detects system problems.

pRECISION FLOW CONTROL INSTRUMENTS-PUNE

Thermal-Mass-Flow-Meters-min.jpg
Slide-1-Flange-Gas-Flow-Meter-With-Remote-Display-min-300x161

Explosion Proof Natural Gas Meter

Digital Natural Gas Meter With Remote Display

Slide-2-Flange-Gas-Flow-Meter-min-300x161

Ex.Proof Natural Gas Meter

Remote Display & With Cable

Slide-3-Gas-Flow-Meter-With-Fittings-min-300x161

Natural Gas Flow Meter

Natural Gas Flow Meter With Cable and Display

0.5 Inch Natural Gas Meter

Flow = 10 m3/hr
  • Flow Rate :5 Digits & Totaliser : 8 Digits
  • Volume Flowrate in m3/hr or Mass Flowrate In Kg/hr
  • 0 to 10 Bar Pressure

1 Inch Natural Gas Flow Meter

Flow = 25 m3/hr
  • Flow Rate :5 Digits & Totaliser : 8 Digits
  • Volume Flowrate in m3/hr or Mass Flowrate In Kg/hr
  • 0 to 10 Bar Pressure

1.5 Inch Natural Gas Meter

Flow = 40 m3/hr
  • Flow Rate :5 Digits & Totaliser : 8 Digits
  • Volume Flowrate in m3/hr or Mass Flowrate In Kg/hr
  • 0 to 10 Bar Pressure

2 Inch Natural Gas Meter

Flow = 100 m3/hr
  • Flow Rate :5 Digits & Totaliser : 8 Digits
  • Volume Flowrate in m3/hr or Mass Flowrate In Kg/hr
  • 0 to 10 Bar Pressure

2.5 Inch Natural Gas Meter

Flow =160 m3/hr
  • Flow Rate :5 Digits & Totaliser : 8 Digits
  • Volume Flowrate in m3/hr or Mass Flowrate In Kg/hr
  • 0 to 10 Bar Pressure

3 Inch Natural Gas M

Flow = 250 m3/hr
  • Flow Rate :5 Digits & Totaliser : 8 Digits
  • Volume Flowrate in m3/hr or Mass Flowrate In Kg/hr
  • 0 to 10 Bar Pressure

Each Flow Meter Is Pre Caliberated and Very Easy For Installiations.

1465236978_resolutions-04.png

Fast Delivery

As A Manufacture We Keep a Powerful Inventory in Ready Stock.From 1 Inch to 6 Inch Flow Meters Are Usually Stocked.So We Can Easily Keep The Promises For Fastest Delivery’s.

1465237056_resolutions-21.png

Leading Exporter

We are Leading Exporters . We are Exporting All Over The World,

1465236987_resolutions-16.png

Cost Effective Prices

As a Indian Manufacturer, We Have Our Prices Very Competative.

We Have Presence in Cities and Abroad With Our Clients and Dealers

Delhi ,Bangalore ,Hyderabad ,Ahmedabad ,Chennai ,Kolkata ,Surat,Pune,Jaipur,Lucknow,Kanpur,Nagpur,Indore,Thane,Bhopal,

Visakhapatnam,Pimpri&Chinchwad,Patna,Vadodara,Ghaziabad,Ludhiana,Agra,Nashik,Faridabad,Meerut,Rajkot,Kalyan&Dombivali,

VasaiVirar,Varanasi,AndhraPradesh,ArunachalPradesh,Assam,Bihar,Chhattisgarh,Goa,Gujarat,Haryana,HimachalPradesh,

JammuandKashmir,Jharkhand,Karnataka,Kerala,MadhyaPradesh,Maharashtra,Manipur,Meghalaya,Mizoram,Nagaland,Odisha,

Punjab,Rajasthan,Sikkim,TamilNadu,Telangana,Tripura,UttarPradesh,Uttarakhand,WestBengal,AndamanandNicobarIslands,

Chandigarh,DadarandNagarHaveli,DamanandDiu,Delhi,Lakshadweep,Puducherry,Ahmedabad,Australia,Bengaluru,HongKong,

Chennai,China,Coimbatore,Egypt,SouthKorea,Delhi,India,Nigeria,Thailand,Goa,Gurugram,Guwahati,Hyderabad,Indore,Jaipur,Jodhpur,

Kanpur,Kerala,Kochi,Kolkata,Lucknow,Australia,Hungary,Mangalore,Mumbai,Malaysia,Oman,Kazakhstan,Nagpur,Nashik,

NewDelhi,Noida,SaudiArabia,Patna,Qatar,Vietnam,Pune,Raipur,Rajkot,Kenya,Solapur,Srinagar,Surat,Thiruvanthapuram,Taiwan,

Tiruchurappalli,Tirupati,Udaipur,Vadodara,Varanasi,Vijayawada,Visakhapatnam,UAE,

uPDATED-hEADER-min1-1
error: Alert: Content is protected !!